九家欧洲眼科中心的三焦点前瞻性多中心非对照研究结果

植入衍射型三焦点IOL后的视力结果与患者满意度评估

作者:Javier Mendicute, MD, PhD, Alexander Kapp, MD, Pierre L_evy, MD, Gero Krommes, MD,Alfonso Arias-Puente, MD, PhD, Mark Tomalla, MD, Elena Barraquer, MD, PhD, Pascal Rozot, MD,Pierre Bouchut, MD

发表期刊:J Cataract Refract Sur

 

重点
提升视力:双眼植入后双眼未矫正远视力、未矫正中视力、未矫正近视力均有明显提升。
较高(90%以上)的患者满意度。 
所有距离,包括中距离的眼镜非依赖(90%以上)。 
摘要
目的

植入衍射三焦点IOL后临床结果的评估

背景

九家欧洲眼科中心

设计

前瞻性多中心非对照研究

方法

双眼植入三焦点衍射型AT LISA tri 839MP IOL,术后1个月和3个月通过感知光现象能力、患者满意度及眼镜依赖评估单眼和双眼的视觉效果。

结果

104名患者208只眼睛植入IOL。术后1个月和3个月,平均双眼未矫正视力分别从0.44logMAR±0.30(SD)提高到0.02±0.10logMAR和0.03±0.09logMAR(p < .01),平均双眼未矫正中视力(80 cm)分别从0.51±0.30logMAR提高到0.09±0.13logMAR和0.10±0.15logMAR(p < .01),平均双眼未矫正近视力分别从0.67±0.31logMAR提高到0.16±0.14logMAR和0.15±0.14logMAR(p< .01)。光晕成为感知光现象中较频繁的部分,但是,约75%的患者并没有被其困扰。超过90%的患者对术后结果很满意。超过90%的患者在所有距离均非依赖眼镜。

结论

该IOL在包括中距离的所有距离均提供优质的视觉效果和可预测的较高屈光结果,并具有很高的患者满意度和眼镜非依赖。

 

Evaluation of visual outcomes and patient satisfaction after implantation of a diffractive trifocal intraocular lens

Author:Javier Mendicute, MD, PhD, Alexander Kapp, MD, Pierre L_evy, MD, Gero Krommes, MD,Alfonso Arias-Puente, MD, PhD, Mark Tomalla, MD, Elena Barraquer, MD, PhD, Pascal Rozot, MD,Pierre Bouchut, MD

Journal:J Cataract Refract Surg

 

Highlights
Improved visual outcomes: Significant vision improvement after monocular implantation:UCDV、UCIV、UCN
More than 90% of patients were satisfied with the outcome 
More than 90% of patients were satisfied with the outcome 
Abstract
PURPOSE

To evaluate clinical outcomes after the implantation of a diffractive trifocal intraocular lens (IOL)

SETTING

Nine European ophthalmology centers

DESIGN

Prospective noncomparative interventional multicenter study

METHODS

The trifocal diffractive AT LISA tri 839MP IOL was implanted in eyes with bilateral cataract. Monocular and binocular visual performance was assessed as was the level of perceived photic phenomena, patient satisfaction, and spectacle dependence 1 month and 3 months postoperatively

RESULTS

The IOL was implanted in 208 eyes of 104 patients. The mean binocular uncorrected distance visual acuity improved from 0.44logMAR±0.30(SD) to 0.02±0.10logMAR and 0.03±0.09logMAR at 1 month and 3 months, respectively (p < .01). The mean binocular uncorrected intermediate visual acuity (80 cm) improved from 0.51±0.30logMAR to 0.09±0.13logMAR and 0.10±0.15logMAR at 1 month and 3 months, respectively (p < .01). The mean binocular uncorrected near visual acuity improved from 0.67±0.31logMAR to 0.16±0.14logMAR and 0.15±0.14logMAR, respectively (p< .01). Among the more frequently perceived photic phenomena were halos; however, approximately 75% of patients were not bothered by them. More than 90% of patients were satisfied with the outcome. Spectacle independence at all distances was higher than 90%.

CONCLUSION

This IOL provided excellent visual outcomes and high refractive predictability at all distances, including intermediate, leading to high levels of patient satisfaction and spectacle independence.

 

来源:蔡司三焦点

沪公网安备 31011002004103号